The PointMax I/O architecture offers a diverse array of input and output modules suitable for various applications, including machine, hybrid, and process control. This architecture employs Producer/Consumer technology, enabling the sharing of input data and output status across multiple Logix 5000 controllers. PointMax I/O systems function as remote I/O modules in conjunction with Logix 5000 controllers. Configuration of the modules is performed using the Studio 5000 Logix Designer application.

A PointMax I/O system consists of one EtherNet/IP adapter and supports up to 32 I/O modules. A 5034-EXP or 5034-EXPXT expansion power is required when using more than 16 I/O modules. The I/O modules are mounted on an MB and require an RTB to connect field-side wiring.

Digital and Analog I/O module

Catalog number Description
5034-IB16 5034-IB8XT 16-point digital input module
5034-IB8 5034-IB8XT 8-point digital input module
5034-OB16 5034-OB16XT 16-point digital output module
5034-OB8 5034-OB4XT 8-point digital output module
5034-OB4 5034-OB4XT 4-point digital output with 2 A module
5034-OW4I 5034-OW4IXT 4-channel relay output isolated 2 A module
5034-UB8 5034-UB8XT 8-point configurable digital input/output module
5034-UB8F 5034-UB8FXT 8-point fast configurable digital input/output module
5034-IF8C 5034-IF8CXT 8-channel analog input current module
5034-IF8V 5034-IF8VXT 8-channel analog input voltage module
5034-IF4 5034-IF4XT 4-channel analog input voltage/current module
5034-IF4IH 5034-IF4IHXT 4-channel analog input HART isolated module
5034-IRT4I 5034-IRT4IXT 4-channel analog input RTD/Thermocouple isolated module
5034-OF4 5034-OF4XT 4-channel analog output module
5034-OF4IH 5034-OF4IHXT 4-channel analog output HART isolated module

Safety I/O module

Catalog number Description
5034-IB8S 5034-IB8SXT 8-point safety digital input module
5034-OB8S 5034-OB8SXT 8-point digital input module

Specialty I/O module

Catalog number Description
5034-IOL4 5034-IOL4XT 4-channel IO-Link master module
5034-ENC 5034-ENCXT 1-channel high-speed counter/SSI encoder module
5034-SERIAL 5034-SERIALXT 1-channel serial RS-232/422/485 module
Specialty IO module

Adapters, bases and Expansion power

Catalog number Description
5034-AENTR 5034-AENTRXT EtherNet/IP™ RJ45 adapter Supports up to 32 PointMax I/O modules
5034-MB 5034-MBXT Mounting base 15 mm
5034-MBSA 5034-MBSAXT Mounting base 15 mm with SA power
5034-MBPTM 5034-MBPTMXT Mounting base with power terminal module
5034-EXP 5034-EXPXT Expansion power module and field

Removable Terminal Block

Catalog number Description
5034-RTB18 EtherNet/IP™ RJ45 adapter Supports up to 32 PointMax I/O modules
5034-RTB18S Mounting base 15 mm
5034-RTBT Mounting base 15 mm with SA power
5034-RTBTS Mounting base with power terminal module
5034-RTB24S Expansion power module and field

Accessories

Catalog numberDescription
5034-AENRTB-QTY56-pin removable terminal block screw for EtherNet/IP adapter - Pack of 5
5034-AENRTBS-QTY56-pin removable terminal block spring for EtherNet/IP adapter - Pack of 5
5034-RTB2-QTY52-pin removable terminal block screw for MBSA mounting base - Pack of 5
5034-RTB2S-QTY52-pin removable terminal block spring for MBSA mounting base - Pack of 5
5034-SHIELD-QTY5Shield clamp - Pack of 5
5034-WIREHLD-QTY5Wirehold - Pack of 5
5034-ECR-QTY5End cap - Pack of 5
5034-N-QTY5Filler module - Pack of 5
5034-KEY-QTY5Removable terminal block keying - Pack of 5

Features and Benefits

  • Modular design with up to 32 modules in one I/O rack
  • Suitable for operating temperatures at -25...+60 °C (-13...+140 °F), and with XT variants for harsh environments rated to GX
  • Multiple network architecture and topology options such as Parallel Redundancy Protocol (PRP), Device Level Ring (DLR), Linear, and Star
  • Consistent design experience with tags and data structure common across the 5000 series I/O architecture
  • Efficient commissioning and maintenance with the use of near-field communication (NFC) technology for IP configuration
  • Enabled by HART and IO-Link technologies coupled with streamlined device integration, simplifying smart machine development
  • Minimal downtime through easy module replacement with Removal and Insertion Under Power (RIUP) and online configuration
  • Availability of Technology Partner modules for expanded technological offerings
  • Compatible with CompactLogix 5380, CompactLogix 5480 and ControlLogix 5580 controllers, using Studio 5000 Logix Designer application version 36 or later.

Studio 5000 Logix Designer Software

Studio 5000 Logix Designer Software

The PointMax I/O architecture provides a wide range of input and output modules to span many applications, such as machine, hybrid, and process control. The architecture uses Producer/Consumer technology that allows input information and output status to be shared among multiple Logix 5000 controllers. PointMax I/O systems are used as remote I/O modules with Logix 5000 controllers. You configure the modules with the Studio 5000 Logix Designer application.

The 5034 PointMax I/O modules integrate seamlessly with Allen-Bradley CompactLogix and ControlLogix platforms. Configuration is handled through Studio 5000 Logix Designer, where modules can be added via the I/O tree, configured, and programmed with ease. The automatic recognition of modules simplifies deployment and minimizes setup time.

Applications of PointMax I/O Modules

  • Packaging machinery
  • Material handling systems
  • Process automation
  • Food and beverage
  • Pharmaceuticals
  • OEM skid-based systems
  • Building automation
  • Water and wastewater treatment

Conclusion

The Rockwell Automation 5034 PointMax I/O Modules offer a powerful and compact solution for distributed control in industrial applications. Whether you’re designing a new system or expanding an existing one, PointMax I/O provides the flexibility, performance, and reliability needed for modern manufacturing environments.

The Rockwell Automation 5034 PointMax I/O Modules provide a compact, high-density solution for distributed I/O needs, especially in applications where space and proximity to the field devices are critical. Their ability to be mounted remotely, combined with seamless integration into Rockwell Logix control architecture, offers engineers and system designers greater flexibility and efficiency in designing control systems. With their robust diagnostics, easy configuration, and network-ready design, the PointMax modules help reduce wiring complexity, streamline maintenance, and support faster system commissioning. For industries seeking reliable, scalable, and space-efficient I/O solutions, the 5034 PointMax series stands out as a powerful choice in Rockwell Automation’s portfolio.

If you are looking for any Allen Bradley (Rockwell Automation) solutions reach us on contact@asteamtechno.com for Support | Solution | Inquiry | Upgradation | Modification